Coupling
Configurations
Male fitting to port
connections can
be made using four types of configurations:
§ Solid male (MP, MB, MBSPT, etc.).
§ Male swivels (MPX, MBX, MIX).
§ Flanges (FL, FLH, FLC, FLK).
§ Block-style adapters with Lock-
nuts.
Flanges
Flanges are installed using clamp halves/flange
half sets. Use the following procedural steps for proper flange fitting installation:
1. Put a small amount of oil on the O-ring and
place in the groove. Oil will prevent the O-ring from falling out.
2. Place fitting over port.
3. Install clamp halves over flange head and
thread in bolts by hand.
4. Use torque wrench to tighten using crossing
pattern.
5. Torque to manufacturer’s specifications.