Monday, December 5, 2016
Fluid Power - Learn the Terminology
Burst Pressure - The pressure that causes rupture. Reference pressure intended for destructive testing purposes and design safety
factors only.
Fluid Power - Learn the Terminology
Buffing: The partial removal of the hose cover in order to put on a coupling. A stone wheel is
typically used to grind or buff the cover to remove the cover material.
Monday, November 7, 2016
Learn the Terminology
Cut-Off Length: The length of that part of the
coupling not directly in contact with or applied to the hose. Subtract the sum
of the cut-off length of the two couplings from the total length of the
assembly, and you will have the approximate hose-cut length to be replaced.
Dash Size: A shorthand method of denoting the size of a particular end
fitting or the inside diameter of a hose. Measured in 1/16 of an inch (i.e., -4 = 4/16”
or ¼”).Hose Cleanliness – Methods of measurement Part 2
There are three principal methods to measure
the contamination level in a component, circuit, or system:
1) Gravimetric Measurement (ISO 4405)
2) Particle Size Distribution Analysis (ISO 4406 or NAS 1638)
3) Maximum Particle Size Analysis (ISO 4407).
This post will discuss the second method (above).
Particle Size Distribution Analysis (ISO 4406 or NAS1638)
Particle Size Distribution Analysis is a reporting method to gauge both the size and number of contaminant particles in a calculated quantity of hydraulic fluid. A fluid sample is either taken directly out of a hydraulic system or a known quantity of fluid is used to dislodge contaminants out of a hydraulic component. This fluid is run through a particle counting instrument to size and count contaminant particles.
These particle ‘counts’ can then be normalized by comparing the total component volume and to a corresponding ISO 4406 ‘code’ level of particle contamination. Levels of five and 15 microns of contamination are reported on a logarithmic scale corresponding to and ISO 4406 ‘code’ for the number of particles greater than or equal to these respective sizes per milliliter of fluid.
1) Gravimetric Measurement (ISO 4405)
2) Particle Size Distribution Analysis (ISO 4406 or NAS 1638)
3) Maximum Particle Size Analysis (ISO 4407).
This post will discuss the second method (above).
Particle Size Distribution Analysis (ISO 4406 or NAS1638)
Particle Size Distribution Analysis is a reporting method to gauge both the size and number of contaminant particles in a calculated quantity of hydraulic fluid. A fluid sample is either taken directly out of a hydraulic system or a known quantity of fluid is used to dislodge contaminants out of a hydraulic component. This fluid is run through a particle counting instrument to size and count contaminant particles.
These particle ‘counts’ can then be normalized by comparing the total component volume and to a corresponding ISO 4406 ‘code’ level of particle contamination. Levels of five and 15 microns of contamination are reported on a logarithmic scale corresponding to and ISO 4406 ‘code’ for the number of particles greater than or equal to these respective sizes per milliliter of fluid.
Monday, October 24, 2016
Hose Cleanliness – affects Valves, Pumps, System cooling
Valves: Microscopic
contamination (similar to erosion) can mill away tolerances which are used for sealing
purposes. On spring centering valves, the debris may get caught between the valve and
the wall surface. The contamination will cause the slowing down of the motion
of the valve or causing sluggish or adverse mechanical actuation.
Abrasive
particles enter the clearances between moving parts they score and hone the surfaces
to greater tolerances. As these tolerances broaden, system performance is
compromised by pressure losses incurred due to fluid leakage from high to lower
pressures.
The worst
occurrence is when particles that are greater than or equal in size to
the orifice openings become wedged between the two surfaces. The
contamination may cause wear to occur or it may cause the system components to
seize.
Pumps &
drives: Microscopic contamination can mill
away material, creating leak points. These leak points rob the hydraulic system
of pressure and cause poor responsiveness.
System
cooling: Working fluid may not flow through to remove contaminants generated
from metal to metal contact when passages
become blocked. Lower flow rates mean greater heat buildup in systems and
thermal breakdown of the working fluid.
Hose Cleanliness - Origin of Contamination
Origins of
contamination may be from system components, the
hydraulic working fluid, the outside environment, or be generated by the system itself.
These contaminants, some large and some microscopic, can have a profound impact
on the performance and longevity of the hydraulic system.
There are
three principal means through which contamination can
occur in a
typical hydraulic system.
Contamination
can be:
1. Generated
during system operation
2. Built
into the system during assembly
3. Ingested by the system during operation
Monday, October 17, 2016
Blast from the Past